High Quality Fast Shipping Customer Support 1030001 Potter PAAR-B Automatic Air Release with Drip Pan - Brand
New - LOOK
The PAAR-B is an automatic float type air vent used to reduce the amount of air trapped in a pressurized fire sprinkler system. Reducing the amount of air in a fire sprinkler system is essential to help protect the system piping from the effects of corrosion that is often found at the air/water interface in the fire sprinkler system piping. Removing as much air as possible will also have a positive effect on the performance of vane type waterflow detectors. The operation of vane type waterflow detectors can be delayed or prevented if too much air is trapped in the system piping. The intent of the product is to vent as much air from the fire sprinkler system as possible. The PAAR-B provides automatic venting of air as the system is being filled. Furthermore, trapped air can also be vented as the air in the system migrates to the vent location over time. The air vent will automatically close when water reaches the vent. Discharge piping from the air vent valve is piped to a shutoff valve mounted in a water retention pan. The pan retains small amounts of water discharged from the air vent valve during normal operation. If failure of the air vent occurs, discharged water will reach a specified depth in the pan (approximately 1") and a water-soluble fiber element in the shutoff valve dissolves and closes the valve preventing further water discharge. The shutoff valve has a visual indication of operation and a single set of NC contacts rated 24V AC/DC@2A for electronic supervision (Recommended). The shutoff valve is a single-use device and contains no user serviceable parts. The PAAR-B provides a 1/2" NPT connection in the bottom of the pan to allow installers to safely pipe and drain if desired. BUY NOW! Payment
Shipping
Returns We accept payment by any of the following methods: VISA - MASTERCARD - PAYPAL - AMEX - DISCOVERY - G-PAY Please pay as soon as possible after winning an sale, as that will allow us to post your item to you sooner!
We do not ship on weekends and holidays. - When your shipping label is generated a notification will be sent via your email. Tracking number will be included. - International buyers must allow 4-6 weeks for delivery. If still not received by then, please contact us. Delays are often due to the customs process in your country. Import duties, tariffs, and taxes are not included. These charges are the buyers responsibility. If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not.
High Quality Fast Shipping Customer Support ---Model Number: PAAR-B ---Item Number: 1030001 ---UL Listed for Fire Sprinkler Branch line applications per UL subject 2573 - "Automatic Air Release Valves for Fire Protection Service" ---FM Approved for "Automatic Air Release Valve for Sprinkler Systems" ---Provides water retention pan and secondary positive stop shutoff valve eliminating any possibility of water discharge The PAAR-B is an automatic float type air vent used to reduce the amount of air trapped in a pressurized fire sprinkler system. Reducing the amount of air in a fire sprinkler system is essential to help protect the system piping from the effects of corrosion that is often found at the air/water interface in the fire sprinkler system piping. Removing as much air as possible will also have a positive effect on the performance of vane type waterflow detectors. The operation of vane type waterflow detectors can be delayed or prevented if too much air is trapped in the system piping. The intent of the product is to vent as much air from the fire sprinkler system as possible. The PAAR-B provides automatic venting of air as the system is being filled. Furthermore, trapped air can also be vented as the air in the system migrates to the vent location over time. The air vent will automatically close when water reaches the vent. Discharge piping from the air vent valve is piped to a shutoff valve mounted in a water retention pan. The pan retains small amounts of water discharged from the air vent valve during normal operation. If failure of the air vent occurs, discharged water will reach a specified depth in the pan (approximately 1") and a water-soluble fiber element in the shutoff valve dissolves and closes the valve preventing further water discharge. The shutoff valve has a visual indication of operation and a single set of NC contacts rated 24V AC/DC@2A for electronic supervision (Recommended). The shutoff valve is a single-use device and contains no user serviceable parts. The PAAR-B provides a 1/2" NPT connection in the bottom of the pan to allow installers to safely pipe and drain if desired.
1030001 Potter PAAR-B Automatic Air Release with Drip Pan - Brand
New - LOOK
The PAAR-B is an automatic float type air vent used to reduce the amount of air trapped in a pressurized fire sprinkler system. Reducing the amount of air in a fire sprinkler system is essential to help protect the system piping from the effects of corrosion that is often found at the air/water interface in the fire sprinkler system piping. Removing as much air as possible will also have a positive effect on the performance of vane type waterflow detectors. The operation of vane type waterflow detectors can be delayed or prevented if too much air is trapped in the system piping. The intent of the product is to vent as much air from the fire sprinkler system as possible. The PAAR-B provides automatic venting of air as the system is being filled. Furthermore, trapped air can also be vented as the air in the system migrates to the vent location over time. The air vent will automatically close when water reaches the vent. Discharge piping from the air vent valve is piped to a shutoff valve mounted in a water retention pan. The pan retains small amounts of water discharged from the air vent valve during normal operation. If failure of the air vent occurs, discharged water will reach a specified depth in the pan (approximately 1") and a water-soluble fiber element in the shutoff valve dissolves and closes the valve preventing further water discharge. The shutoff valve has a visual indication of operation and a single set of NC contacts rated 24V AC/DC@2A for electronic supervision (Recommended). The shutoff valve is a single-use device and contains no user serviceable parts. The PAAR-B provides a 1/2" NPT connection in the bottom of the pan to allow installers to safely pipe and drain if desired. BUY NOW! We accept payment by any of the following methods: VISA - MASTERCARD - PAYPAL - AMEX - DISCOVERY - G-PAY Please pay as soon as possible after winning an sale, as that will allow us to post your item to you sooner!
We do not ship on weekends and holidays. - When your shipping label is generated a notification will be sent via your email. Tracking number will be included. - International buyers must allow 4-6 weeks for delivery. If still not received by then, please contact us. Delays are often due to the customs process in your country. Import duties, tariffs, and taxes are not included. These charges are the buyers responsibility. If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not.
High Quality Fast Shipping Customer Support |