PB - PICOBOXMM5000 - Message Master 5000Model: RMC5 Remote Monitoring ControllerVersion 1.33.12Critical Alarm Monitoring System Device ID: MM5KMessage Master 5000 is a comprehensive and improved model from its predecessor yet maintains its simplicity, reliability, scalability, quality and ease of use. One of its new features is the capability of receiving and transmitting high level signals from equipment via Modbus RTU, Modbus TCP and SNMP protocols. A trend logging feature was added to help users identify potential efficiency problems on their equipment or even in the whole facility. Its SMS alert sending was improved using 3G network and E-mail alert sending through mobile data which makes it more efficient standalone monitoring system.Product Features: Ease of use - Intuitive user interface - Flexible User configuration - Remote access - Standalone operation - Expandable - Microcontroller based design - Low Power Consumption - Small & Compact - Repeat SMS Automatic Health Check - Remote Phone ManagementSpecifications Physical Name: Message Master 5000 Models: RMC5 Operating Voltage: 9 to 30 VDC, 2W max power consumption Processor: Cortex-A5, 530 MHz Memory: 256 Mbytes DDR2 RAM GSM modem: USB modem Quad Band HSDPA/UMTS (900/2100MHz) Operating Environment: 0-55 degree Celsius, 0-90% non-condensing Size & Weight: 160 (L) x 40 (H) x 100 (D) mm, 500 gm Security Feature: 2 security levels, Administrator and User level Real Time Clock: Date & time with NTP Support LCD Display: 16 x 2 Characters with backlight, selectable status display date and time | Network Status | Device Name | Device ID | Telco Signal Strength | Digital Input State | Digital Input Alarm State Communications port: 1 x RJ45 port, Ethernet 10/100Mbps Interface: Web-based, accessible via web browser softwareNetwork Network Support: Static IP Network Protocol: TCP (Transmission Control Protocol), IP (Intemet Protocol), UDP (User Datagram Protocol) HTTP (Hyper Text Transfer Protocol) DNS (Domain Name Server), SNTP (Simple Network Time Protocol).SMTP ( Simple Mail Transfer ProtocolDigital Inputs No of input points: 12 optically coupled dry contact Configuration: Independent configuration of input description open/close status description Response Time: Individual selection of response time for each input from 0.2 to 3600 secs (trigger sensitivity) Alarm State: Definable normally open (NO) or close (NC) as Alarm conditionRelay Outputs No of Out puts points: 2 relay outputs, contact rated at 24VDC 2A Configuration: User definable output description Output control: Through SMS or Local On/Off relay outputs through web-browser Internal buzzer: Option time interval from 10 to 60 secs on Alarm stateAnalog Input No of Analog points: Configuration: Configurable input description, scaling, trigger delay. high/low alarm points Alarm Delay Time: Individual selection of alarm delay time for each analog 3600 secs (trigger sensitivity)Email Alert Email group: up to 64 email recipients Time stamp: Email sent with time stamp with configurable subject Event Logs Event logging: Stores up to 500 History events with Date and time Stamp, FIFO event recording Data Format: XML (Extensible Markup Language), allows user to define their own tags in excel or web interface Trend Logs Display: Display 4 charts Configuration: Up to 8 tags per chart Minimum log interval of 10 minutesRemote Management Remote Command via SMS: a) Query health check - b) Query input/output/ analog statusc) On/Off/equipment/devices - d) Add/Edit/Delete contacts - e) Query Operational/ Authorizer / Escalation / Forwarder contacts - f) AcknowledgementsSMS Alert Phone Groups: a) 64 mobile phone numbers for operational - b) 8 mobile phone number for ist level escalation c) 8 mobile phone numbers for 2nd level Escalation - d) 8 mobile phone numbers for authorizer e) 1 mobile phone number for Forwarder **Accepts international Phone Numbers format and support Auto Roaming SMS Configuration: Digital inputs, relay outputs & analog inputs (2 messages per input), 1 for Alarm State and 1 for Normal State Auto Health Check: Programmable date & time system health check Time Stamp: SMS sent & received with time stampsPower on and tested item testing pictures are attached.Have some marks and scratches due to old stock.© All the pictures are Organic and this part is physically in our stock.Condition and Details:
This is a used item in good condition.Not in Original Packing
No Accessories / Cables or probe (only what showing in actually given pictures and in the description).
Old Stock.
Shipping:
Usually, we ship same business day, subject to clear funds into our account
Standard order processing time is 2 to 4 business days
Item will be packed as per International Standard,
International Orders: DHL / SingPost / EMS
* Expedited shipping is available for an extra fee.
* International buyers pay all custom, duties, taxes & brokerage fees at their end
Warranty and Returns:
Warranty:
30 DAYS Money Back or Replacement, buyer pays return shipping
Product Returns:
Returns:
Returnto Base Warranty, Any type of power failure/burn / physical damage / tempered seal will void the warranty.
Payment:Payment Methods:PayPalCredit CardsWire-transfer: Kindly contact us for payment instructionsInternational buyers without PayPal: Kindly contact us before bidding
About Us:
We deal in Semiconductor & Wafer Handling Parts/Components/machinery and types of equipment. A Verity of Industrial Automation Equipment and Parts.Industrial PCs, PLCs, HMI, Controllers, and Sensors.Industrial robotics, Data Acquisition, and Test & Measurement.Industrial Single Board Computers.Marine Parts / Equipments.Oil & Gas and offshore station.Lab and Research Equipments.
We Source, We Refurbish, We Service and We also Repair …please contact for any further detailed inquiries.