The TriField EMF Meter Model TF2 is an AC gaussmeter, AC electric field meter, and radio power density meter in a single unit, that combines all the features needed for fast, accurate measurements of electromagnetic fields (EMF). In addition to standard AC measurement modes, a special frequency weighted mode will properly scale the magnetic and electric measurements to indicate the full magnitude of currents produced by each type of field inside the human body.
Features:
- Detects all three types of EMF pollution: AC magnetic, AC electric, and RF/microwave
- Special frequency weighting mode for measuring electric current from EMF in the human body
- AC Magnetic Mode covers 40 Hz – 100 kHz with range of 0.1 – 100.0 milligauss (mG)
- AC Electric Mode covers 40 Hz – 100 kHz with range of 1 – 1000 volts per meter (V/m)
- RF Mode covers 20 MHz – 6 GHz with range of 0.001 – 19.999 milliwatts per square meter (mW/m2)
- AC magnetic measurements are 3-axis, allowing for quick readings, regardless of meter orientation
- Large liquid-crystal display (LCD) for crystal clear, accurate readings
- Adjustable backlight for use in low-light environments
- Audio Indicator emits sound that helps to pinpoint EMF sources
- Peak Hold captures fast pulses, for measuring fast digital signals
- Operates for more than 20 hours on a 9V battery, with a low battery indicator
Applications:
- Mobile phone and cell tower RF radiation
- Smart meter RF radiation
- Wi-Fi router and Bluetooth RF radiation
- Overhead AC power line and transformer EMF emissions
- Laptop, refrigerator, circuit breaker box, etc. appliance EMF emission
- EMF emission inside aircraft and motor vehicles
- Microwave oven leak
- Location and EMF of wiring in walls
- EMF from plumbing pipes used as grounding
Specifications |
TriField® EMF Meter
|
AC Magnetic |
|
3-axis, true magnitude |
|
Frequency Range |
40 Hz – 100 kHz |
|
Accuracy |
±4% @ 50/60 Hz |
|
Maximum Range |
100.0 milligauss |
|
Sensivity (Resolution) |
0.1 milligauss |
AC Electric |
|
1-axis, true magnitude |
|
Frequency Range |
40 Hz – 100 KHz |
|
Accuracy |
±5% @ 50/60 Hz |
|
Maximum Range |
1000 V/m |
|
Sensitivity (Resolution) |
1 V/m |
RF/Microwave |
|
1-axis |
|
Frequency Range |
20 MHz – 6 GHz |
|
Accuracy |
±20% @ 1 GHz |
|
Maximum Range |
19.999 mW/m2 |
|
Sensitivity (Resolution) |
0.001 mW/m2 |
Battery |
|
9V alkaline battery with indicator |
|
Battery Life Backlight Off |
> 20 hrs |
|
Battery Life Backlight On |
> 12 hrs |