Width | 22.5 mm |
---|---|
Height | 99 mm |
Depth | 123 mm |
Ambient temperature (operation) | 0 °C ... 55 °C |
---|---|
Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
Degree of protection | IP20 |
Noise immunity | EN 61000-6-2:2005 |
Electrical isolation | VCC // Ethernet |
---|---|
Test voltage data interface/power supply | 1500 V |
1.5 kVrms (50 Hz, 1 min.) | |
Electromagnetic compatibility | Conformance with EMC directive 89/336/EC |
Noise emission | EN 50081-2 |
Net weight | 171.7 g |
Housing material | PA V0 |
Color | green |
MTBF | 573 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
138 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
ATEX | II 3 G Ex nAC IIC T4 X (Please follow the special installation instructions in the documentation!) |
UL, USA/Canada | Class I, zone 2, AEx nc IIC |
Nominal supply voltage | 24 V DC ±20 % (via pluggable COMBICON screw terminal block) |
---|---|
24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply) | |
Typical current consumption | ≤ 95 mA (24 V DC) |
Protective circuit | Reverse polarity protection |
Connection method | Plug-in screw terminal block (COMBICON), redundancy possible |
Interface 1 | Ethernet interface, 10/100BASE-T(X) in acc. with IEEE 802.3u |
---|---|
Connection method | RJ45 socket, shielded |
Transmission medium | Copper |
Transmission length | 100 m (shielded twisted pair) |
Auto-negotiation modes | Optionally transparent via TP and FO (default) or locally on TP |
Link through | Link down is automatically forwarded to the second connection |
MDI-/MDI-X switchover | Built-in switch for line (1:1) and crossover connection |
Signal LEDs | Activity (yellow), Link status (green), 100 Mbps (green) |
Serial transmission speed | 10/100 Mbps |
Transmit capacity, minimum | min. -23.5 dBm ((50/125 µm) dynamic in link mode (average)) |
---|---|
min. -20 dBm ((62,5/125 µm) dynamic in link mode (average)) | |
min. -20.5 dBm ((50/125 µm) static) | |
min. -17 dBm ((62,5/125 µm) static) | |
Transmit capacity, maximum | max. -14 dBm ((50/125 µm) dynamic in link mode (average)) |
max. -14 dBm ((62,5/125 µm) dynamic in link mode (average)) | |
max. -11 dBm ((50/125 µm) static) | |
max. -11 dBm ((62,5/125 µm) static) | |
Minimum receiver sensitivity | min. -31 dBm (dynamic in link mode (average)) |
min. -28 dBm (static) | |
Wavelength | 1300 nm |
Transmission length incl. 3 dB system reserve | 6.4 km (with F-G 50/125 0,7 dB/km F 1200) |
2.8 km (with F-G 50/125 1,6 dB/km F 800) | |
10 km (with F-G 62,5/125 0,7 dB/km F 1000) | |
3 km (with F-G 62.5/125 2.6 dB/km F 600) | |
2 km (with 2GK200/230 GI-HCS) | |
Transmission medium | Multi-mode fiberglass |
GI-HCS fiber | |
Connection method | B-FOC (ST) |
Electromagnetic compatibility | Conformance with EMC directive 89/336/EC |
---|---|
Noise emission | EN 50081-2 |
Noise immunity | EN 61000-6-2:2005 |
ATEX | II 3 G Ex nAC IIC T4 X |
UL, USA/Canada | Class I, zone 2, AEx nc IIC |