Nellcor N-395 N 395 Medical Patient Monitor Pulse Oximeter Great Condition N395
The Nellcor N-395 Pulse Oximeter with Oxismart XL Advanced Signal Processing reads through challenging motion conditions, cutting through nonspecific noise to find the pulse and track true Sp 02 and pulse rate values.
The N-395 monitor is also equipped with SatSeconds Alarm Management, a breakthrough in clinician-programmable alarm sensitivity for pulse oximetry. SatSeconds Alarm Management empowers clinicians to manage nuisance alarms caused by short or rapid transient desaturations. Clinicians can set SatSeconds Alarm Management to trigger an alarm only when the SatSeconds "clock" reaches a user-defined limit of 0, 10, 25, 50, or 100 SatSeconds. When three or more violations occur in 60 seconds, an alarm will sound, even if the SatSeconds clock setting has not been reached. This is the SatSeconds "safety net".
The N-395 is a portable pulse oximeter intended for use as a continuous non-invasive monitor of functional oxygen saturation of arterial hemoglobin (Sp 0 2) and pulse rate. It is intended for adult, pediatric, and neonatal patients. The N-395 is designed for hospitals, outpatient centers, intra-hospital transport, and home care. Hospital use typically covers such areas as general care floors, operating rooms, special procedure areas, intensive and critical care areas, surgicenters, sub-acute centers, special nursing facilities, sleep labs, and more.
Specifications:
Measurement Range:
Sp 0 2: 1 - 100%
Pulse Rate: 20 to 250 beats per minute (bmp)
Accuracy
Saturation (%Sp 0 2)+-1SD)
Without Motion
Adults: 70 - 100% +-2digits
Neonates: 70 - 100%+-3digits
1-69% unspecified
With Motion
Adults & Neonates: 70-100%+-3digits
1-69% unspecified
Pulse Rate
Without Motion: 20-250+-3digits
With Motion: Normal physiologic range (e.g., 55-125bpm)+-5digits
Electrical
Instrument
Power Requirements: 100-120 VAC, 200-240 VAC, 50/60 Hz, 20 VA switch selectable.
Fuses: 2 qty, .5 A, 250 volts, slow-blow, IEC (5x20mm)
Battery: Lead-Acid
Battery Capacity: A minimum of 2 hours with a new fully charged battery under the following conditions: no alarms, and no analog or serial output devices attached. A completely discharged battery can be fully recharged in approximately 14 hours while unit is turned off or 18 hours while turned on.
Charge/discharge cycles: at least 400
Sensor: The wavelength range of the light emitted is within the range of 250 nm to 1,000 nm with the energy not exceeding 10nw.
Item turns on and says "EEE4 low battery".